LX2V Series PLC

LX2V-1212-MR-A 12xDI/12xDO   (1 BD Board)

LX2V-1212-MT-A 12xDI/12xDO    (1 BD Board)

LX2V-1410-MR-A 14xDI/10xDO    (1 BD Board)

LX2V-1410-MT-A 14xDI/10xDO    (1 BD Board)

LX2V-1412-MR-A 14xDI/12xDO    (1 BD Board)

LX2V-1412-MT-A  14xDI/12xDO    (1 BD Board)

LX2V-1616-MR-A 16xDI/16xDO     (2 BD Board)

LX2V-1616-MT-A  16 xDI/16xDO     (2 BD Board)

LX2V-1814-MR-A 16xDI/14xDO      (2 BD Board)

LX2V-1814-MT-A 18 xDI 14xDO       (2 BD Board)

LX2V-2416-MR-A 24xDI/16xDO      (2 BD Board)

LX2V-2416-MT-A 24 xDI/16xDO       (2 BD Board)

LX2V-2424-MR-A 24 xDI/24xDO       (2 BD Board)

LX2V-2424-MT-A 24 xDI/24xDO        (2 BD Board)

LX2V-3624-MR-A  36 xDI/24xDO      (2 BD Board)

NOTE:- “No RTC, No Expansion Module, No High speed I/P Or O/P”

CPU :  STM32 CPU,

Sensor Power Supply : DC-24V(400mA)

Main Power Supply :AC100-240V/50-60Hz,DC 24V(Optional)

Communication port :  support RS422 & RS485, 2 serial port,

Communication protocol :  support FX2N NO PROTOCOL, programming software support FX2N

Environment temperature : 0~55°C

General

Running Mode Scan round / Interrupt
Programming Instruction List / Ladder
Total Instructions Basic Instructions: 27 Applied Instruction: 136+2 (2 instructions different from Mitsubishi)
Execute Time Basic Instructions: 0.06us /Applied Instruction: 1~10us
Program Capacity 16K
Download / Monitor Serial Programming Cable/ Mini USB
High Pulse Output Transistor Type: 2 Channels / Relay Type: N/A
High Speed Counter 6 Channels
Timer Interrupt 3 Channels
Latched Addresses Adjustable
Storage FLASH
Digital Filtering Yes, for all input terminal
Serial Port COM1 RS422 or RS485
Serial Port COM2 RS485
Environment Tempeture Operating Temperature:0 ~ 55℃/Storage Temperature:-20 ~ 70℃
Operating Humidity 35~85%RH (No-condensate)
Shock Resistance JIS C 0040 Standard
Noise Immunity Noise Voltage: 1000Vp-p Pulse Width: 1us Frequency: 30-100Hz (Noise Simulator)

Output

Output Type No
Input Power Supply DC 24V
Output Circuit  
COM Port Current No
Insulation Mechanistic
Leak current No
Min. Load No
Resistive 2A / point, 8A / COM port
Inductive 80VA
General 100W
ON / OFF Response Time <10ms

AC Power Supply

Voltage Range AC 100V~240V 50Hz~ 60Hz, DC 24V±10%
Power Outage Time 10ms
Inrush Current <15A 1ms / DC 24V, <15A 5ms (AC100V) <30A 5ms (AC 200V)
Power Fuse 250V/1A (AC Power Supply), 250V/3.15A (DC Power Supply)
Power Consumption <30W (DC Power Supply), <35W (AC Power Supply)
Power Output DC 24V 850mA

Click here to View Product Manual